Using the System Utilities
Using the EISA Configuration Utility
NCR S10 Desktop Server User Guide 5-21
The parameters are described in Table 5-3. The /B, /H,
/M, and /K parameters are explained in Table 5-2.
Table 5-3
Configure Computer Selection
Parameters
Parameter Function Description
/N Non-target modeling
mode
This parameter runs the utility in non-target
modeling mode. When you run this utility, the
configuration which is stored in the SYSTEM.SCI
file displays.
When you save the configuration, it is normally
saved to the SYSTEM.SCI file. However, with
non-target modeling mode, you can create an SCI
file for a computer other than the one on which
you are running the utility, create multiple SCI
files, and create one SCI file for multiple
computers.
/T Detailed view by slot This parameter causes the default view to be
detailed by slot instead of overview.
/F Fast configuration
operation
This is the automatic configuration mode. The
utility determines the boards and options and
configures the system without user assistance.